Leak test set DPK 60-5 from AFRISO

Categories:

The AFRISO DPK 60-5 leak testers are designed for measurements of gaseous media as well as for tightness tests and load tests of low-pressure gas pipes in non-hazardous areas. The mechanical test set can be used for easy tightness tests (150 mbar) and load tests (1 bar) on gas pipes and for checking the connection and flow pressure. In addition, the test set is also suitable for tightness tests (150 mbar) and strength tests (3 bar) on drinking water pipes as per ZVSHK (German Central Association of the HVAC Industry).

The AFRISO DPK 60-5 leak testers are suitable for tests on gas/liquid gas pipes as well as drinking water pipes as per German ZVSHK. The set is contained in a robust plastic case.

The AFRISO DPK 60-5 leak testers are suitable for tests on gas/liquid gas pipes as well as drinking water pipes as per German ZVSHK. The set is contained in a robust plastic case.

The AFRISO DPK 60-5 leak testers are designed for measurements of gaseous media as well as for tightness tests and load tests of low-pressure gas pipes in non-hazardous areas. The mechanical test set can be used for easy tightness tests (150 mbar) and load tests (1 bar) on gas pipes and for checking the connection and flow pressure.

In addition, the test set is also suitable for tightness tests (150 mbar) and strength tests (3 bar) on drinking water pipes as per ZVSHK (German Central Association of the HVAC Industry). The scope of delivery of the DPK 60-5 leak test set comprises two pressure gauges, one pressure test valve with quick-action coupling and high-precision adjustment valve, a bulb pump with valve and silicone hose, two conical test plugs with plug-in nipples, three connection hoses with quick-action coupling and plug-in nipple as well as a Y connector with shut-off valve, quick-action couplings and plug-in nipple. The filling pressure can be easily adjusted via the high-precision pressure test valve. The quick-action coupling system ensures easy and fast adaptation to the task at hand.

The DPK 60-5 leak test set can be used for acceptance tests of heating system pipes or solar system pipes, underfloor heating systems, gas / liquid gas pipes and waste water pipes as well as pressure adjustments/tests or vacuum/tightness tests of oil pipes and oil pumps. The compact, cost-effective set is ideal for starters in the area of tightness testing.

Pressure transducer DMU 08 T and data logger DL 10 from AFRISO in combination

Categories:

Monitoring waste water systems, rain overflow facilities, rivers and waters, wells, drilling holes or drinking water treatment plants is possible with little financial and technical effort. You only need a measuring instrument and an evaluation system such as the DMU 08 T pressure transducer and the DL 10 data logger with display from AFRISO. The combination is suitable for electronic, continuous level and temperature measurement of drinking water, groundwater, waste water (with optional FEP cable), diesel fuel and fuel oil.

The combination of DMU 08 T pressure transducer and DL 10 data logger from AFRISO allows for cost-effective monitoring of waste water systems, rain overflow facilities, rivers and water, wells, drilling holes or drinking water plants.

The combination of DMU 08 T pressure transducer and DL 10 data logger from AFRISO allows for cost-effective monitoring of waste water systems, rain overflow facilities, rivers and water, wells, drilling holes or drinking water plants.

Monitoring waste water systems, rain overflow facilities, rivers and waters, wells, drilling holes or drinking water treatment plants is possible with little financial and technical effort. You only need a measuring instrument and an evaluation system such as the DMU 08 T pressure transducer and the DL 10 data logger with display from AFRISO.

The combination is suitable for electronic, continuous level and temperature measurement of drinking water, groundwater, waste water (with optional FEP cable), diesel fuel and fuel oil. DMU 08 T converts the pressure of liquids in the pressure ranges of 0/100 mbar to 0/25 bar and temperatures of 0/30 °C to 0/70 °C into proportional 4-20 mA signals. A special feature is the ability to measure level and temperature with separate, independent signal amplification. In conjunction with the DL 10 data logger, a freely programmable, digital display unit with four analogue, independently programmable sensor inputs (for example, for two DMU 08 T), as well as comprehensive data logger functionality, the pressure and temperature values can be displayed with a single display. The data logger which supplies the transducer DMU 08 T has a supply voltage range of AC 50-253 V and DC 20-253 V for universal application. DL 10 features a standard rack mounting housing for control panel mounting and a backlit LC display for excellent readability even at unfavourable light conditions.

A simple and intuitive user interface with multiple languages (EN, DE, FR) ensures fast commissioning.
The combination of DMU 08 T and DL 10 meets all requirements in terms of a complete measuring system with process display and data logger. All data can be transferred to a PC.